REP 2.1 User Interface Assembly
Parts List on (32-55 ppm) PL 2.15, (65-87 ppm) PL 2.10.
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
CAUTION
Ensure that E.S.D. procedures are observed during the removal and installation of the user
interface assembly.
1.
Open the front door, PL 8.10 Item 10.
2.
Remove the user interface assembly, Figure 1.
WorkCentre 5687 Family
1
Remove 2 screws
Figure 1 User interface assembly
Replacement
1.
The replacement is the reverse of the removal procedure. Refer to GP 6 before the
screws are installed to the user interface assembly.
2.
If prompted, reload the software set, GP 4. The WorkCentre and WorkCentre Pro will
automatically upgrade or downgrade the software when the machine is switched on, GP
14.
August 2007
4-27
2
Disconnect PJ130
and PJ81
Repairs/Adjustments
REP 2.1