REP 14.7B Scan Cables (65-87 ppm)
Parts List on PL 14.16.
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the scan carriage, REP 14.5B.
2.
Remove the scan motor cover PL 14.16 Item 10, (2 screws).
3.
Slide the cables off the pulleys or capstan.
4.
Remove the springs and lift out the cables.
Replacement
1.
Figure 1 shows the general arrangement of the scan cables, when correctly installed.
Lower scan cable
Note that the springs are in
the same relative position.
Figure 1 Scan cable arrangement
Repairs/Adjustments
REP 14.7B
2.
Figure 2. Prepare to install the lower scan cable.
NOTE: The lower scan cable is black and is longer than the upper scan cable.
NOTE: The anchor ball is not installed centrally on the scan cables.
NOTE: To assist in holding the scan cables in position, use adhesive tape.
short end
6 turns on
each cable
Upper scan
cable
Figure 2 Mount lower scan cable on the capstan
August 2007
4-586
long end
longer, black cable
1
Wind three turns below the anchor
point on the capstan.
2
Install the anchor ball in the anchor
point
3
Use adhesive tape to secure the anchor ball in the anchor point