Short screw
Long screw with earth tag
Figure 1 Solenoid removal
Replacement
CAUTION
Ensure the short and long screw are installed in the correct location, Figure 1.
Reverse the removal procedure to replace the tray hold solenoid assembly.
NOTE: Ensure that the solenoid is positioned on the locating dowels.
WorkCentre 5687 Family
REP 11.31-130 CC Stapler Mount and Traverse Shaft
Assembly
Parts List on PL 11.48
Removal
Take care during this procedure. Sharp edges may be present that can cause injury.
Switch off the electricity to the machine GP 14. Disconnect the power cord from the cus-
tomer supply while performing tasks that do not need electricity. Electricity can cause
death or injury. Moving parts can cause injury.
1.
2.
3.
4.
1
Disconnect harness
3
Remove solenoid and linkage
2
Remove 2 screws
August 2007
4-303
WARNING
WARNING
Remove the compiler carriage, REP 11.2-130.
Remove the staple head assembly, REP 11.3-130.
Remove the stapling unit traverse motor, REP 11.26-130.
Figure 1, remove the stapler mount and traverse shaft assembly.
REP 11.30-130, REP 11.31-130
Repairs/Adjustments