REP 11.2-171 HVF Stapler Assembly
Parts List on PL 11.140
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply, while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Slide the HVF away from the IOT.
2.
Remove the HVF front door, REP 11.1-171.
3.
Remove the HVF top cover, REP 11.1-171.
4.
Remove the HVF front cover, REP 11.1-171.
5.
Remove the rear cover, REP 11.1-171.
6.
Figure 1. At the rear of the HVF, disconnect three connectors and remove one screw
securing the grounding strap.
1
Disconnect three PJs
REAR VIEW
Figure 1 Disconnect PJs and remove screw
Repairs/Adjustments
REP 11.2-171
7.
Figure 2. With the power cord disconnected, it is possible to reach behind the stapler and
move the ejector unit to the out position, by turning the encoder of the ejector unit motor,
MOT11-020 in the direction indicated.
2
Remove grounding
strip screw
August 2007
4-440
Turn the encoder wheel
Stapler (shown
in faint lines)
Figure 2 Move ejector to the out position
WorkCentre 5687 Family