REP 11.35-170 CC Entrance Baffle and Springs
Parts List on PL 11.74
Removal
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
WARNING
Switch off the electricity to the machine GP 14. Disconnect the power cord from the cus-
tomer supply while performing tasks that do not need electricity. Electricity can cause
death or injury. Moving parts can cause injury.
1.
Remove the compiler sensor, REP 11.34-170.
2.
Refer to REP 11.4-170, remove the carriage PWB from its mounting but do not disconnect
any PJs from the PWB.
3.
Figure 1, remove the CC entrance baffle.
WorkCentre 5687 Family
1
Remove 2
springs
5
Remove the baffle
Figure 1 Removing the entrance baffle
Replacement
Reverse the removal procedure to replace the CC entrance baffle.
August 2007
4-379
2
Unhook spring
3
Disconnect the ground wire
4
Remove 4 screws
Repairs/Adjustments