REP 14.9B Input Module Angle Sensor (65-87 ppm)
Parts List on PL 14.15.
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the scanner top cover, REP 14.2B.
2.
Figure 1, remove the input module angle sensor.
3
Disconnect the sensor from
the harness and remove
Figure 1 Input module angle sensor
Replacement
1.
Reverse the removal procedures to replace the input module angle sensor.
2.
When replacing the input module angle sensor, ensure that the lugs on the sensor are
located in the slot of the frame before tightening the screw.
WorkCentre 5687 Family
2
Depress the actuator
to release the sensor
1
Remove one screw
August 2007
4-591
REP 14.10B Exposure Lamp and Exposure Lamp Inverter
(65-87 ppm)
Parts List on PL 14.15.
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the document glass, the CVT glass and the CVT ramp assembly, REP 14.3B.