REP 8.7 Duplex Transport
Parts List on (32-55 ppm) PL 8.22, (65-87 ppm) PL 8.20
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
WARNING
Take care during this procedure. Motors will become hot during normal operation.
1.
Remove the duplex transport, Figure 1.
3
Pull out and remove
the duplex transport
2
Pull the transport out by 75 mm
(3 inches) and disconnect the
harness
Figure 1 Duplex transport removal
Replacement
1.
Replacement is the reverse of the removal procedure. Refer to GP 6 before refitting the
screw to the duplex transport.
2.
Go to 01A Ground Distribution RAP. Check the grounding of the duplex transport.
Repairs/Adjustments
REP 8.7
3.
Check that the duplex transport is located correctly on the metal channel, Figure 2.
4.
After completing the replacement procedure, perform the dC604 Registration Setup.
NOTE: Lift the left side of the transport to engage the support pin through the rear frame.
1
Remove screw.
August 2007
4-116
Duplex transport
Duplex transport
Metal channel.
Figure 2 Duplex transport location
WorkCentre 5687 Family