Xerox WorkCentre 5687 Series Service Manual page 1295

Table of Contents

Advertisement

1
Carefully push the
lever past the shaft
to rest against the
inner baffle
3
Carefully bend the centre of the diverter gate upwards and
remove
Figure 2 Diverter gate removal
Replacement
Reverse the removal procedure to install the diverter gate.
WorkCentre 5687 Family
REP 11.13-130 Mylar Guide Assembly
2
Parts List on PL 11.40
Push the diverter gate fully to
Purpose
the rear
This procedure is used to repair the following parts:
Removal
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply, while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
2.
3.
4.
5.
6.
August 2007
4-275
Mylar guide reel, PL 11.40 Item 4.
Mylar guide torsion spring, PL 11.40 Item 5.
Mylar guide clamp, PL 11.40 Item 7.
Pulley gear, PL 11.40 Item 9.
Drive belt, PL 11.40 Item 10.
Shaft, PL 11.40 Item 15.
Mylar guide, PL 11.40 Item 16.
WARNING
Open the HCSS front door and cheat the front door interlock. Enter dC330 code 11-016 to
move the compiler carriage to the lowest position.
WARNING
Remove the HCSS top cover, rear cover and front door, REP 11.1-130.
Remove bin 0, PL 11.30 Item 15.
Remove the bin 1 assembly, REP 11.5-130.
Remove the upper paper guide, REP 11.11-130.
Figure 1, release the mylar guide.
REP 11.12-130, REP 11.13-130
Repairs/Adjustments

Hide quick links: