11-198-171, 11-199-171 HVF Paper Jam RAP

11-198-171 A stray sheet was detected in the finisher, after a jam clearance.
11-199-171 An unexpected sheet has been detected in the finisher.
Initial Actions
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
Check for a jam or other obstruction in the HVF paper path.
Check the paper path for damage.
Procedure
Figure 1. shows the location of the components.
Enter dC330, code 11-100. Manually activate the entry sensor, Q11-100, Figure 1. The
play changes.
Y
N
Go to Flag 1. Check the sensor, Q11-100.
Refer to:
GP 11 How to Check a Sensor.
P/J101, HVF Control PWB
11A-171 HVF Power Distribution RAP
Install new components as necessary:
Entry sensor, PL 11.156.
HVF Control PWB, PL 11.157 Item 2.
Enter dC330, code 11-157. Manually activate the buffer position sensor, Q11-157, Figure 1.
The display changes.
Y
N
Go to Flag 2. Check the sensor, Q11-157.
Refer to:
GP 11 How to Check a Sensor.
P/J101, HVF Control PWB
11A-171 HVF Power Distribution RAP
Install new components as necessary:
Buffer position sensor, PL 11.156.
HVF Control PWB, PL 11.157 Item 2.
Enter dC330, code 11-164. Manually activate the buffer path sensor, Q11-164, Figure 1. The
display changes.
Y
N
Go to Flag 3. Check the sensor, Q11-164.
Refer to:
GP 11 How to Check a Sensor.
P/J101, HVF Control PWB
A
WorkCentre 5687 Family
A
11A-171 HVF Power Distribution RAP
Install new components as necessary:
Buffer path sensor, PL 11.156.
HVF Control PWB, PL 11.157 Item 2.
Enter dC330, code 11-140. Manually activate the stacker exit sensor, Q11-140, Figure 1. The
display changes.
Y
N
Go to Flag 4. Check the sensor, Q11-140.
Refer to:
GP 11 How to Check a Sensor.
P/J101, HVF Control PWB
11A-171 HVF Power Distribution RAP
Install new components as necessary:
Stacker exit sensor, PL 11.156.
HVF Control PWB, PL 11.157 Item 2.
dis-
Enter dC330, code 11-130. Manually activate the top exit sensor, Q11-130, Figure 1. The dis-
play changes.
Y
N
Go to Flag 5. Check the sensor, Q11-130.
Refer to:
GP 11 How to Check a Sensor.
P/J101, HVF Control PWB
11A-171 HVF Power Distribution RAP
Install new components as necessary:
Top exit sensor, PL 11.156.
HVF Control PWB, PL 11.157
Enter dC330, code 11-158. Manually activate the HVF booklet exit sensor, Q11-158, Figure 1.
The display changes.
Y
N
Go to Flag 6. Check the sensor, Q11-158.
Refer to:
GP 11 How to Check a Sensor.
P/J101, HVF Control PWB
11A-171 HVF Power Distribution RAP
Install new components as necessary:
HVF booklet exit sensor, PL 11.156
HVF Control PWB PL 11.157 Item 2.
The fault may be intermittent, check for damaged wiring or bad connectors, REP 1.2. If neces-
sary install new components.