2.
Remove the nudger and the feed roll from the front. Slide the tray 5 module away from the
machine and remove the retard roll, Figure 1.
1
Lift the tab and slide the nudger and
feed roll off the drive shaft
Figure 1 Remove the feed rolls
WorkCentre 5687 Family
1
Lift the tab and slide the retard roll
off the drive shaft
August 2007
4-153
Replacement
1.
The replacement is the reverse of the removal procedure. Refer to GP 6 before refitting
the screws.
2.
Ensure that the tabs on the feed roll are located in the drive shaft.
3.
Check the registration, refer to dC604 Registration Setup Procedure.
4.
If a new nudger / feed and retard roll are installed, reset the tray 5 feeds count to zero in
the HFSI feature screen. Refer to GP 17 High Frequency service Items.
Repairs/Adjustments
REP 8.34