REP 11.39-171 HVF BM Diverter Gate
Parts List on PL 11.153
Removal
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply, while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
1.
Remove the HVF front door, REP 11.1-171.
2.
Remove the HVF top cover, REP 11.1-171.
3.
Remove the HVF front cover, REP 11.1-171.
4.
Remove the HVF rear cover, REP 11.1-171.
5.
Figure 1. At the rear of the HVF, remove the solenoid arm, the K-L clip and the bush from
the diverter shaft.
3
2
Remove the bush
Remove the K-L clip
REAR VIEW
Figure 1 Removal preparation
WorkCentre 5687 Family
6.
Figure 2. Remove the BM diverter gate.
1
Pull the solenoid arm
Replacement
from the shaft
The replacement procedure is the reverse of the removal procedure.
August 2007
4-493
1
Open Guide 5d
2
Remove the
pivot screw
3
Remove the
diverter
Figure 2 Diverter removal.
Repairs/Adjustments
REP 11.39-171