Xerox WorkCentre 5687 Series Service Manual page 1194

Table of Contents

Advertisement

Transfer wire
Figure 3 Spiral wrap location
2.
Position the ground wire terminal in the left hand screw location on the hinge bracket and
position the HT leads, Figure 4.
3.
When locating the hinge bracket to the frame make sure that the hinge is pushed fully
against the frame.
4.
To ensure that the transport hinge is located correctly, first install the left hand screw, with
the ground wire, then the right hand screw.
Repairs/Adjustments
REP 10.1
Detack wire with plastic
sleeve
5.
6.
August 2007
4-174
NOTE: Ensure that both ends of the ground lead are connected to the correct terminals.
Position of the ground wire tag
Figure 4 Ground wire and spiral wrap
After completing the replacement procedure, check that the short paper path assembly
latches without excessive force.
Raise and lower the latch mechanism of the short paper path assembly, PL 10.25 Item 1,
to ensure that the transfer / detack corotron is parallel to the photoreceptor. If the move-
ment of raising the short paper path assembly is not smooth, check the action of the
corotron carrier PL 10.25 Item 2.
Position of the HT leads
WorkCentre 5687 Family

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wc5632fWc5545fWc5675fWc5645fWc5687fWc5655f

Table of Contents