Replacement
1.
The replacement is the reverse of the removal procedure.
2.
If a new duplex sensor is installed, reset the Duplex sensor count to zero in the HFSI fea-
ture screen. Refer to GP 17 High Frequency service Items.
3.
(65-87 ppm). Check that the tension spring is located correctly on the upper transport
guide. Install the duct on the duplex transport. Check that the sensor wires pass through
the cut-out in the duct and are not caught under the duct. Figure 3.
Check that the wires pass
through the cut out in the duct
Figure 3 Duplex transport duct
WorkCentre 5687 Family
Check that the tension spring
is located correctly
August 2007
4-151
REP 8.33 Tray 5 Transport Drive Belt
Parts List on PL 8.40
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the rear cover, PL 7.60 Item 9.
2.
Prepare to remove the drive belt, Figure 1.
5
Release the motor assembly from the drive belt
Figure 1 Preparation
1
Remove two screws
2
Remove E-clip
3
Loosen the screw to
release belt tensioner
4
Remove two screws
Repairs/Adjustments