11-465-171 to 11-468-171 Paddle Unit Position RAP

11-465-171 The paddle unit has failed to return to the upper position.
11-466-171 The paddle unit has failed to move from the upper position.
11-467-171 The paddle unit has failed to return to the lower position.
11-468-171 The paddle unit has failed to move from the lower position.
Initial Actions
Check for damage or obstructions that would prevent the paddle unit from operating correctly.
Procedure
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
NOTE: All HVF BM interlocks must be made to supply +24V to the motors.
Enter dC330, code 11-027 paddle unit motor, MOT11-027, Figure 1. Select code 11-027 and
press Start. The motor runs.
Y
N
Go to Flag 2. Check MOT11-027.
Refer to:
GP 10, How to Check a Motor.
P/J202, HVF control PWB.
11A-171, HVF Power Distribution RAP.
Install new components as necessary:
Paddle unit motor, PL 11.150.
HVF control PWB, PL 11.157 Item 2.
Enter dC330, code 11-027 to check the paddle unit motor, MOT11-027, Figure 1. The paddle
unit moves.
Y
N
Check the drive gears on the paddle unit. Install new components as necessary. PL
11.145 Item 2.
Enter dC330, code 11-194 paddle unit upper sensor, Q11-194. Select code 11-194 and press
Start. Select code 11-027 and press Start. The sensor status changes.
Y
N
Go to Flag 1. Check Q11-194.
Refer to:
GP 11 How to Check a Sensor.
P/J201, HVF control PWB.
11A-171, HVF Power Distribution RAP.
Install new components as necessary:
Paddle unit upper sensor, PL 11.145.
A
WorkCentre 5687 Family
A
HVF control PWB, PL 11.157 Item 2.
Enter dC330, code 11-195 paddle unit lower sensor, Q11-195. Select code 11-195 and press
Start. Select code 11-027 and press Start. The sensor status changes.
Y
N
Go to Flag 3. Check Q11-195.
Refer to:
GP 11 How to Check a Sensor.
P/J201, HVF control PWB.
11A-171, HVF Power Distribution RAP.
Install new components as necessary:
Paddle unit lower sensor, PL 11.145.
HVF control PWB, PL 11.157 Item 2.
Perform SCP 6 Final Actions.
August 2007
2-633
Status Indicator RAPs
11-465-171 to 11-468-171