Xerox WorkCentre 5687 Series Service Manual page 1468

Table of Contents

Advertisement

4.
Remove the front tamper base and front support finger, Figure 2.
1
Front Tamper
Base
Remove the screw
and clip
Figure 2 Front Support Finger
Repairs/Adjustments
REP 11.8-171
Finger Guide
2
Rotate the finger to dis-
engage the pin from the
guide slot.
August 2007
5.
Remove the guide and the rear support finger, Figure 3.
Figure 3 Rear Support Finger
Replacement
Reverse the removal procedure to replace the front or rear support fingers.
NOTE: Set the front and rear support fingers so that their ends are aligned when extended.
See Figure 4.
With the pressing plate installed, set the front and rear support finger alignment, Figure 4. If the
fingers are not aligned, the compiler output will be uneven and cause exit jams.
4-448
Rotate the finger to disen-
gage the pin from the guide
slot - see Figure 2.
Rear support finger guide
WorkCentre 5687 Family