REP 11.44-170 Docking Latch Components
Parts List on PL 11.64
Purpose
This procedure is used to repair the following components
•
Docking release latch, PL 11.64 Item 13.
•
Release bracket, PL 11.64 Item 11.
•
Docking interlock switch, PL 11.64 Item 3.
•
Docking pivot interlock switch, PL 11.64 Item 5.
•
Restraining cable, PL 11.64 Item 1.
Removal
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
WARNING
Switch off the electricity to the machine GP 14. Disconnect the power cord from the cus-
tomer supply while performing tasks that do not need electricity. Electricity can cause
death or injury. Moving parts can cause injury.
1.
Un-dock the HCSS from the machine, REP 11.13-170.
2.
Figure 1, release the restraining cable.
Repairs/Adjustments
REP 11.44-170
4
Open the bracket as
far as possible
Figure 1 Restraining cable
3.
Figure 2, remove the docking latch bracket rear cover.
August 2007
4-394
1
Release the latch, open
the bracket fully
2
Remove screw
3
If a new restraining
cable is being installed,
remove the screw
WorkCentre 5687 Family