Xerox WorkCentre 5687 Series Service Manual page 1353

Table of Contents

Advertisement

REP 11.6-170 HCSS BM Castors
Parts List on PL 11.60
Removal
WARNING
Switch off the electricity to the machine GP 14. Disconnect the power cord from the cus-
tomer supply while performing tasks that do not need electricity. Electricity can cause
death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Un-dock the HCSS BM from the machine, REP 11.13-170.
2.
If removing the rear non-adjustable castor, remove the rear cover, REP 11.1-170.
3.
Figure 1, remove a non-adjustable castor.
WorkCentre 5687 Family
3
Remove the screw
1
Place two reams of
paper at the front or rear
of the HCSS BM
2
Remove the screw.
Figure 1 Removal of non-adjustable castors
4.
To remove an adjustable castor, remove the front and rear covers, REP 11.1-170 and
then remove the two screws holding the right foot cover, Figure 2.
August 2007
4-333
Repairs/Adjustments