REP 1.9 LVPS and Base Module
Parts List on PL 1.10
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the power and control assembly, REP 1.1.
2.
Remove the HVPS, (2 screws) and the IOT PWB, (8 screws), from the old LVPS and base
module.
3.
Remove the insulating sheet from behind the HVPS.
4.
Figure 1. Remove the output device harness and tray 5 harness from the LVPS and base
module.
Repairs/Adjustments
REP 1.9
1
Remove 4 hex
head screws
Figure 1 Remove the output device harness and tray 5 harness
Replacement
Do not over tighten the four hex head screws. The screws break very easily.
1.
The Replacement procedure is the reverse of the Removal procedure.
August 2007
4-22
2
Disconnect PJ 515
3
Remove the output device
harness and tray 5 harness
CAUTION
WorkCentre 5687 Family