REP 10.20 Inverter Sensor
Parts List on (65-87 ppm) PL 10.12
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the inverter assembly, REP 10.2.
2.
Remove the inverter sensor, Figure 1.
1
Follow the sequence to remove
the sensor
2
Disconnect the harness from the
sensor
Tab to secure the
harness
Figure 1 Remove the inverter sensor
Repairs/Adjustments
REP 10.20
Replacement
1.
The replacement is the reverse of the removal procedure. Refer to GP 6 before refitting
the screws.
2.
Route the harness under the tab on the upper baffle, Figure 1.
3.
Make sure that the upper baffle and the inverter assembly duct are linked correctly. When
the latch 3d/4d is released, the two items lift together.
August 2007
4-206
WorkCentre 5687 Family