4.
Release the harness and remove the fuser exit switch, Figure 3.
2
Release the harness
Figure 3 Remove the fuser exit switch
Replacement
The replacement is the reverse of the removal procedure. Refer to GP 6 before refitting the
screws.
1.
On the 65-87 ppm machines, make sure that the harness and the connector are routed
away from the spring, Figure 4.
Repairs/Adjustments
REP 10.16
1
Remove the
screw
2.
On all machines. Check for 5mm clearance between the anti-rotation bracket and the
heater lamp wires, Figure 4. Inspect the heater lamp wires for damage. If the wires are
damaged install a new fuser module.
August 2007
4-200
Anti-rotation bracket
Harness connector
Harness
Spring
Figure 4 Harness location 65-87 ppm