IQS 1 Solid Area Density
Documents
Test patterns: 82E2000 (A3 and 11X17) 82E2010 (A4) 82E2020 (8.5X11) and the solid area
density scale, 82E8230 (SIR 542.00) for reference.
Specification
Compare the copies of one of the above 82E series test patterns, Figure 1, made from the doc-
ument glass, with the solid area density scale, 82E8230 (SIR 542.00). The density of the 2.1;
2.3; and 2.5 areas must be as dark or darker than the 1.3 reference, but less than 1.5.
Compare a print of the internal test pattern 12, Figure 2, with the solid area density scale,
82E8230 (SIR 542.00). The density of the solid areas must be as dark or darker than the 1.3
reference, but less than 1.5.
Corrective action
If the solid area density specification is not met, then go to the IQ1 Image Quality Entry RAP.
Figure 2 Internal test pattern 12
SIR 542.00
82E2000
Figure 1 Test patterns
Image Quality RAPs
August 2007
IQS 1
WorkCentre 5687 Family
3-23