Remove the circlip
and the developer
drive gear
Remove the idler
Remove the circlip and
rolls
the registration trans-
port drive gear
Figure 3 Remove drive gears and idlers
Replacement
CAUTION
The spring loaded belt tensioner, Figure 1 is a floating type and should not be locked down.
Replacement is the reverse of the removal procedure.
If a new developer drive gear is installed, reset the developer count to zero in the HFSI feature
screen. Refer to GP 17 High Frequency service Items.
Repairs/Adjustments
REP 4.3A
Remove the cir-
clip, paper path
drive gear and
spring
Remove the circlip
and the fuser drive
gear
August 2007
4-50
WorkCentre 5687 Family