Release the tension of the mylar guide
3
Carefully allow the mylar guide
to be rolled upwards by the
spring
Figure 1 Release the mylar guide
7.
Figure 2, loosen the belt tensioner.
Repairs/Adjustments
REP 11.13-130
2
Move the metal end
of the guide towards
the front or rear and
unhook from the
hole in the compiler
carriage frame
8.
Figure 3, remove the mylar guide reel bearings.
August 2007
4-276
1
Loosen screw 3 turns
Figure 2 Belt tensioner