Hvf Bm Paper Jam Rap - Xerox WorkCentre 5687 Series Service Manual

Table of Contents

Advertisement

11-183-171, 11-184-171 HVF BM Paper Jam RAP

11-183-171 The BM control PWB has detected an unexpected sheet in the booklet maker
paper path.
11-184-171 The BM control PWB has detected a stray sheet in the booklet maker paper path
after jam clearance.
Initial Actions
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
Check for a jam or other obstruction in the booklet maker paper path.
Check the paper path for damage.
Procedure
Figure 3. shows the location of the components.
Enter dC330 code 11-190. Manually actuate the BM paper present sensor, Q11-190, Figure 1.
The display changes.
Y
N
Go to Flag 1. Check the sensor, Q11-190.
Refer to:
GP 11, How to Check a Sensor.
P/J556, BM PWB.
11A-171 HVF Power Distribution RAP.
Install new components as necessary:
BM PWB, PL 11.166 Item 10.
BM paper present sensor, PL 11.168 Item 5.
Enter dC330 code 11-409. Manually actuate the BM exit sensor, Figure 2. The
changes.
Y
N
Go to Flag 2. Check the sensor, Q11-409.
Refer to:
GP 11, How to Check a Sensor.
P/J556, BM PWB.
11A-171 HVF Power Distribution RAP.
Install new components as necessary:
BM PWB, PL 11.166 Item 10.
BM exit sensor, PL 11.168 Item 17.
Enter dC330 code 11-160. Manually actuate the BM entry sensor, Q11-160, Figure 1. The dis-
play changes.
Y
N
Go to Flag 3. Check sensor, Q11-160.
A
Status Indicator RAPs
11-183-171, 11-184-171
A
Refer to:
GP 11, How to Check a Sensor.
P/J551, BM PWB.
11A-171 HVF Power Distribution RAP.
Install new components as necessary:
BM PWB, PL 11.166 Item 10.
BM entry sensor, PL 11.161 Item 16.
Enter dC330 code 11-183. Manually actuate the tri-folder entry sensor, Q11-183, Figure 3.
The display changes.
Y
N
Go to Flag 4. Check the sensor, Q11-183.
Refer to:
GP 11, How to Check a Sensor.
P/J604, tri-folder control PWB.
11A-171 HVF
+Power Distribution RAP.
Install new components as necessary:
Tri-folder control PWB, PL 11.193 Item 16.
Tri-folder entry sensor, PL 11.197 Item 11.
Enter dC330 code 11-183. Manually actuate the tri-folder entry sensor., Q11-183. The
play changes.
Y
N
Go to Flag 5. Check between P/J602 pin 10 on the tri-folder control PWB and P/J563 pin
1 on the BM PWB.
Refer to:
P/J563, BM PWB.
P/J602, Tri-folder control PWB
11A-171 HVF Power Distribution RAP.
display
Install new components as necessary:
BM PWB, PL 11.166 Item 10.
Tri-folder control PWB, PL 11.193 Item 16.
B
August 2007
2-578
dis-
WorkCentre 5687 Family

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wc5632fWc5545fWc5675fWc5645fWc5687fWc5655f

Table of Contents