REP 9.2 Developer Assembly
Parts List on (32-55 ppm) PL 9.17, (65-87 ppm) PL 9.15
Removal
WARNING
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove left hand cover, PL 8.10 Item 3.
2.
Disconnect PJ93 and the developer bias lead, Figure 1.
1
Disconnect PJ93
Figure 1 Developer bias leads
3.
Remove the developer module, Figure 2.
Repairs/Adjustments
REP 9.2
2
Disconnect developer bias
lead
August 2007
4-160
3
2
Remove two screws and remove
Remove the xerographic module and
the developer module
place in a black bag
Figure 2 Remove the developer assembly
1
Turn the latch
WorkCentre 5687 Family