4.
Remove the inverter path solenoid link, Figure 3.
NOTE: When the link arm has been removed, a new link arm must be installed, PL 10.11
Item 1.
Figure 3 Inverter path solenoid link
WorkCentre 5687 Family
5.
Remove the inverter gate, Figure 4.
1
Use a screwdriver
to remove the link
Replacement
Re-install the remainder of the removed components. Replacement is the reverse of the
removal procedure. Refer to GP 6 before refitting the screws.
August 2007
4-189
1
Rotate and then remove the inverter gate
Figure 4 Inverter gate