Woodward easYgen-2000 Series User Manual page 554

Genset control
Hide thumbs Also See for easYgen-2000 Series:
Table of Contents

Advertisement

Appendix
LogicsManager Reference > Logical Outputs
Name
Inhibit emergency run
Undelay close GCB
Constant idle run
External acknowledge
Operation mode AUTO
Operation mode MAN
Operation mode STOP
Start without load
Automatic idle mode
Discrete f/P +
Discrete f/P -
Discrete V/PF +
Discrete V/PF -
Freq. Droop active
Volt. Droop active
Critical mode
Firing speed
Frequency setpoint 2
Load setpoint 2
Voltage setpoint 2
Power factor setpoint 2
Enable MCB
Load-dependent start/stop
Segment no.2 act
LDSS Priority 2
LDSS Priority 3
LDSS Priority 4
Transition mode 1
554
Function
Blocking or interruption of an emergency power operating in AUTOMATIC operating
mode (parameter
12200 Ä p.
Immediately closing of the GCB after engine start without waiting for the engine delayed
monitoring and generator stable timer to expire (parameter
Enables idle/rated speed modes (parameter
The alarm acknowledgement is performed from an external source (param‐
eter
12490 Ä p.
180)
Activation of the AUTOMATIC operating mode (parameter
Activation of the MANUAL operating mode (parameter
Activation of the STOP operating mode (parameter
Starting the engine without closing the GCB (parameter
Automatic idle mode (blocks the undervoltage, underfrequency, and underspeed moni‐
toring for a configured time automatically, parameter
Raise frequency / real power setpoint (parameter
Lower frequency / real power setpoint (parameter
Raise voltage / power factor setpoint (parameter
Lower voltage / power factor setpoint (parameter
Activation of the frequency droop (parameter
Activation of the voltage droop (parameter
Activation of critical mode operation (parameter
Firing (ignition) speed is reached (parameter
Activates the frequency setpoint 2 (parameter
Activates the load setpoint 2 (parameter
Activates the voltage setpoint 2 (parameter
Activates the power factor setpoint 2 (parameter
Enables the MCB (parameter
Activation of load-dependent start/stop (parameter
Assigns the genset to load share segm. #2 (parameter
Sets the LDSS priority to 2 (parameter
Sets the LDSS priority to 3 (parameter
Sets the LDSS priority to 4 (parameter
Activates breaker transition mode 1 (parameter
easYgen-2200/2500 | Genset Control
245)
12210 Ä p.
12550 Ä p.
243).
12510 Ä p. 247
12520 Ä p.
12530 Ä p.
12540 Ä p.
12570 Ä p.
12900 Ä p.
12901 Ä p.
12902 Ä p.
12903 Ä p.
12904 Ä p.
275)
12905 Ä p.
290)
12220 Ä p.
12500 Ä p.
239)
12918 Ä p.
275)
12919 Ä p.
280)
12920 Ä p.
289)
12921 Ä p.
12923 Ä p.
206)
12930 Ä p.
12929 Ä p.
12926 Ä p.
252)
12925 Ä p.
253)
12924 Ä p.
253)
12931 Ä p.
201)
204)
)
247)
248)
247)
243)
307)
307)
307)
307)
268)
294)
252)
303)
Number
00.11
00.12
00.14
00.15
00.16
00.17
00.18
00.19
00.20
00.21
00.22
00.23
00.24
00.25
00.26
00.28
00.29
00.81
00.82
00.83
00.84
00.85
00.86
00.87
00.90
00.91
00.92
00.93
37535B

Advertisement

Table of Contents
loading

Table of Contents