ID
Parameter
4216
Hysteresis
4207
Delay
4201
Alarm class
4202
Self acknowl‐
edge
4203
Delayed by
engine speed
Parameter IDs
Flexible
Descrip‐
Moni‐
limit #
tion
toring
1
4208
4200
2
4225
4217
3
4242
4234
4
4259
4251
5
7108
4270
6
7116
4280
37535B
CL
Setting range
Description
[Default]
Notes
Refer to
limit.
2
0 to 32000
During monitoring, the actual value must exceed or fall below one of the limits
defined in parameter
[1]
limits. For a value to register as having returned to the permissible limits, the
monitored value must rise above or fall below this value for the hysteresis.
The format for entering the hysteresis depends on the monitored analog input
and corresponds with the one of the threshold listed in param‐
eter
2
00.02 to 327.00
If the monitored value exceeds or falls below the threshold value for the delay
s
time configured here, an alarm will be issued. If the monitored value falls
below the threshold (plus/minus the hysteresis, dependent on param‐
[1.00 s]
eter
2
Class A/B/C/D/
Each limit may be assigned an independent alarm class that specifies what
E/F
action should be taken when the limit is surpassed.
[B]
Notes
For additional information refer to
on page 587
2
Yes
The control unit automatically clears the alarm if the fault condition is no
longer detected.
[No]
The control unit does not automatically reset the alarm when the fault condi‐
tion is no longer detected.
The alarm must be acknowledged and reset by manually pressing the appro‐
priate buttons or by activating the LogicsManager output "External acknowl‐
edgement" (via a discrete input or via an interface).
2
Yes
Monitoring for fault conditions is not performed until engine delayed moni‐
toring is enabled. The engine monitoring delay time (param‐
eter
parameters assigned this delay.
[No]
Monitoring for this fault condition is continuously enabled regardless of engine
speed.
Moni‐
Moni‐
tored
toring at
analog
input
4206
4204
4223
4221
4240
4238
4257
4255
4276
4274
4286
4284
easYgen-2200/2500 | Genset Control
Configure Monitoring > Flexible Limits
Ä "Examples" on page 178 for examples on how to configure the
4205 Ä p. 176
4205 Ä p.
176.
4204 Ä p.
176) before the delay expires the time will be reset.
Ä Chapter 9.5.1 "Alarm Classes"
3315 Ä p.
239) must expire prior to fault monitoring being enabled for
Limit
Hyste‐
Delay
resis
4205
4216
4207
4222
4233
4224
4239
4250
4241
4256
4267
4258
4275
4278
4277
4285
4288
4287
Configuration
to be recognized as out of permissible
Alarm
Self
class
acknowl‐
edge
4201
4202
4218
4219
4235
4236
4252
4253
4271
4272
4281
4282
Delayed
by
engine
speed
4203
4220
4237
4254
4273
4283