Technical Specifications
Technical Data > Inputs/Outputs
Currents
8.1.2

Ambient Variables

8.1.3

Inputs/Outputs

Discrete inputs
474
Measuring frequency
Accuracy
Input resistance per path
Maximum power consumption per path
Measuring inputs
Measuring current
Accuracy
Linear measuring range
Maximum power consumption per path
Rated short-time current (1 s)
Power supply
Intrinsic consumption
Degree of pollution
Maximum elevation
Overvoltage (≤ 2 min)
Reverse voltage protection
Input capacitance
Discrete inputs
Input range (Vcont. dig. input)
Input resistance
easYgen-2200/2500 | Genset Control
50/60 Hz (30.0 to 85.0
Hz)
Class 1
120 V
0.498 MΩ
480 V
2.0 MΩ
< 0.15 W
Isolated
[1] Rated value (I
)
../1 A
rated
[5] Rated value (I
)
../5 A
rated
Class 1
Generator
3.0 × I
Mains/ground current
approx. 1.5
× I
< 0.15 VA
[1]
50.0 × I
[5]
10.0 × I
12/24 Vdc (8 to 40.0 Vdc)
easYgen-2200: ~ 8 W
easYgen-2500: ~ 12 W
2
2,000 m ASL
80 Vdc
Full supply range
easYgen-2200: 660 uF
easYgen-2500: 990 uF
Isolated
Rated voltage
12/24 Vdc (8 to 40.0 Vdc)
approx. 20 kΩ
rated
rated
rated
rated
37535B