Generic Note; Environmental Data - Woodward easYgen-2000 Series User Manual

Genset control
Hide thumbs Also See for easYgen-2000 Series:
Table of Contents

Advertisement

Technical Specifications

Environmental Data

8.1.8

Generic Note

8.2
Environmental Data
Vibration
Shock
Temperature
Humidity
Marine environmental categories
478
Accuracy
Frequency range - sine sweep
Acceleration
Standards
Frequency range - random
Power intensity
RMS value
Standards
Shock
Standards
Cold, Dry Heat (storage)
Cold, Dry Heat (operating)
Standards
Humidity
Standards
Marine environmental categories
easYgen-2200/2500 | Genset Control
Referred to full scale value
5 Hz to 100 Hz
4 G
EN 60255-21-1 (EN 60068-2-6, Fc)
Lloyd's Register, Vibration Test2
SAEJ1455 Chassis Data
10 Hz to 500 Hz
0.015 G²/Hz
1.04 Grms
MIL-STD 810F, M514.5A, Cat.4,
Truck/Trailer tracked-restrained
Cargo, Fig. 514.5-C1
40 G, Saw tooth pulse, 11 ms
EN 60255-21-2
MIL-STD 810F, M516.5, Procedure 1
-30 °C (-22 °F) / 80 °C (176 °F)
-20 °C (-4 °F) / 70 °C (158 °F)
IEC 60068-2-2, Test Bb and Bd
IEC 60068-2-1, Test Ab and Ad
MILSTD -810D, M501.2 Induced,
M502.2 Cold
LR Dry Heat, Cold, Envt 2,4, DNV Dry
heat, Cold Class A,C
95%, non condensing
MIL-STD 810D, M507.2, PII
Lloyd's Register of Shipping (LRS):
ENV1, ENV2, ENV3 and ENV4
37535B

Advertisement

Table of Contents
loading

Table of Contents