Maintenance Commands
Sequence Count - This number indicates the order of errors logged
Seq Cnt
within a second for the time stamps associated with the first
occurrence and last occurrence of an error. This information is
displayed only if the high-resolution command line option is entered.
There may be gaps for the sequence numbers within a given second
since the last occurrence of an error may replace an existing entry
that had been assigned the missing sequence number. Gaps may
also appear in the numbers since sequence counts are also used with
software event information not shown in the hardware error log.
Displays the month, day, hour, and minute (and second if the
Last Occur
high-resolution command line option is used) of the most recent error.
Note: if the system is unable to retrieve the time of day when the error
occurred, a 'dummy' date will be stamped in the log and appears as:
00/00/01:07.
Error Count - The total number of times that the error type has
Err Cnt
occurred for this maintenance object. If the number of errors exceeds
3 digits, the system enters the number 256, which indicates that a
larger number of errors occurred, but could not be displayed correctly.
Error Rate - The average rate at which the errors have occurred from
Err Rt
the first occurrence to the present. If the number of errors exceeds 3
digits, the system enters the number 256, which indicates that a larger
number of errors occurred, but could not be displayed correctly.
Rate per Hour - An approximation of the rate that this error occurred
Rt/Hr
in the last hour.If the number of errors exceeds 3 digits, the system
enters the number 256, which indicates that a larger number of errors
occurred, but could not be displayed correctly.
Alarm Status - A character indicating the status of this MO in the error
Al St
and alarm logs. The allowed values are:
Active? - A y (yes) entry indicates the maintenance object is still
Ac
active. A n (no) entry indicates the object is no longer a problem.
224
Issue 5 October 2002
a
Active alarm entry
r
Resolved alarm entry
c
Resolved alarm entry as a result of the long "clear" option of
the test command
s = Resolved alarm entry as a result of a software requested
(non-demand) system restart
t
Resolved alarm entry as a result of a technician requested
system restart
n
Not alarmed.