Calibrating With Wrist Optimization Method - ABB IRB 8700 Product Manual

Hide thumbs Also See for IRB 8700:
Table of Contents

Advertisement

5.5 Calibrating with Wrist Optimization method

When to run Wrist Optimization
Wrist Optimization routine is run to improve TCP reorientation performance.
Calibrating the robot with standard calibration method overwrites the optimized
positions of axes 4, 5. Re-run the Wrist Optimization routine after standard
calibration to re-achieve the optimized positions of the wrist axes.
Overview of the calibration procedure on the FlexPendant
The actual instructions of how to perform the calibration procedure and what to
do at each step is given on the FlexPendant. You will be guided through the
calibration procedure, step by step.
Use the following list to learn about the calibration procedure before running the
RobotWare program on the FlexPendant. It gives you a brief overview of the
calibration procedure sequence.
After the calibration method has been called for on the FlexPendant, the following
sequence will be run.
Product manual - IRB 8700
3HAC052853-001 Revision: M
1 Choose calibration routine Wrist Optimization.
2 Modify targets for 4-point tool frame definition, in Wrist Optimization routine.
a Jog the robot to an appropriate position,
A, for the first approach point.
Use small increments to accurately posi-
tion the tool tip as close to the reference
point as possible.
b Tap Modify Position to define the point.
c Repeat for each approach point to be
defined, positions B, C, and D.
Jog away from the fixed world point to
achieve the best result. Just changing the
tool orientation will not give as good a
result.
3 Improved calibration data to the wrist axes is identified and presented.
4 Optimized positions for the wrist axes are presented.
5 The robot moves to the optimized positions for the wrist axes and
automatically overwrites previous calibration data.
WARNING
Robot moves automatically when pressing Calibrate.
6 Wrist optimization is finished.
7 Redefine / verify TCP for all tools.
© Copyright 2015-2020 ABB. All rights reserved.
5.5 Calibrating with Wrist Optimization method
en0400000906
5 Calibration
715

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 8700 - 550/4.20Irb 8700 - 800/3.50

Table of Contents