Action
Refit the cable gland cover.
Note
Replace the gasket if damaged.
Connect the connectors.
Connect in accordance with the markings
on the connectors.
Inspect the o-ring.
Note
Replace if damaged.
CAUTION
When refitting the motor cover, make sure
that none of the cables inside will be dam-
aged.
© Copyright 2015-2020 ABB. All rights reserved.
4.5.1 Replacing the upper arm
Note
Attachment screws: M5x16 (2 pcs)
xx1200001016
xx1200001015
O-ring: 3HAC054692-002
xx1200001070
Continues on next page
4 Repair
Continued
279