4 Repair
4.5.1 Replacing the upper arm
Continued
3
4
Continues on next page
270
Action
Use Isopropanol to wipe clean the surfaces
of following parts:
contact surfaces and the glycerin
adapter connection on the shaft
contact surfaces in the holes for the
shafts, outer ring of bearings and
sealing rings.
Note
Do not touch the cleaned surfaces with
anything after cleaning.
Inspect the sealing rings and then wipe
them clean with Isopropanol. Replace if
damaged.
© Copyright 2015-2020 ABB. All rights reserved.
Note
Isopropanol
xx1500002749
xx1500002979
xx1500002750
xx1500002748
Product manual - IRB 8700
3HAC052853-001 Revision: M