ABB IRB 8700 Product Manual page 194

Hide thumbs Also See for IRB 8700:
Table of Contents

Advertisement

4 Repair
4.4.1 Removing the cable harness
Continued
Equipment, etc.
Sparkplug wrench
Removing the cable harness
Use these procedures to remove the cable harness.
Preparations before removing the cable harness
1
2
3
4
Retrieving access to the wrist cabling
1
Continues on next page
194
Action
Note
The specified position is a recommended
position. Depending on what tool is used,
one or more axes need to be jogged into
another position.
Note
In order to avoid that the spiral of the cable
harness in the carrier is being unwound or
placed in the wrong position, keep axis-5
as close as possible to +90°.
Jog the robot to the specified position:
Axis 1: 0°
Axis 2: comfortable working position
Axis 3: comfortable working position
Axis 4: 0°
Axis 5: +90°
Axis 6: Depending on which tool is
used, if still fitted.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
© Copyright 2015-2020 ABB. All rights reserved.
Article number
Note
-
Used to remove and refit the R1.SMB
in the base.
Note
Note
Product manual - IRB 8700