4
Refitting the brake release unit
Use these procedures to refit the brake release unit.
1
2
3
4
Product manual - IRB 8700
3HAC052853-001 Revision: M
Action
Remove the brake release unit from the bracket, if it
should be replaced.
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
read the safety information in section
sensitive to ESD on page
Fasten the brake release unit to the bracket.
Refit the bracket with the brake release unit fitted.
Make sure the unit is placed as straight as possible
on the bracket. The push buttons can otherwise get
jammed when the SMB cover is refitted.
Reconnect the connectors X8, X9 and X10 to the
brake release unit.
Be careful not to damage the sockets or pins.
Make sure the connector and its locking arms are
snapped down properly.
© Copyright 2015-2020 ABB. All rights reserved.
4.4.4 Replacing the brake release unit