ABB IRB 8700 Product Manual page 182

Hide thumbs Also See for IRB 8700:
Table of Contents

Advertisement

4 Repair
4.2.3 Mounting instructions for sealings
Continued
4
Flange sealings and static sealings
The following procedure describes how to fit flange sealings and static sealings.
1
2
3
4
O-rings
The following procedure describes how to fit o-rings.
1
2
Continues on next page
182
Action
Mount the sealing correctly with a mounting tool.
Never hammer directly on the sealing as this may
result in leakage.
Action
Check the flange surfaces. They must be even and free from pores.
It is easy to check flatness using a gauge on the fastened joint (without sealing com-
pound).
If the flange surfaces are defective, the parts may not be used because leakage could
occur.
Clean the surfaces properly in accordance with the recommendations of ABB.
Distribute the sealing compound evenly over the surface, preferably with a brush.
Tighten the screws evenly when fastening the flange joint.
Action
Ensure that the correct o-ring size is used.
Check the o-ring for surface defects, burrs,
shape accuracy, or deformation.
© Copyright 2015-2020 ABB. All rights reserved.
Note
A
xx2000000072
A Gap
Note
Defective o-rings, including damaged
or deformed o-rings, may not be used.
Product manual - IRB 8700
3HAC052853-001 Revision: M