Inspecting the oil level in axis-4 primary gearbox
1
2
3
4
5
6
7
8
Product manual - IRB 8700
3HAC052853-001 Revision: M
3.3.3 Inspecting the oil level in axis-4 primary gearbox
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working
area.
WARNING
Handling gearbox oil involves several safety risks,
see
Gearbox lubricants (oil or grease) on page
CAUTION
The gearbox can contain an excess of pressure
that can be hazardous. Use caution when the oil
plug is opened, in order to let out the excess
pressure.
Open the ventilation plug.
Note
The ventilation plug shall be opened prior to the
inspection plug, in order to release possible
pressure inside.
Open the inspection plug.
Inspect the oil level.
Required oil level is a few millimeters below the
lower edge of the inspection hole.
Add or drain oil, if required.
© Copyright 2015-2020 ABB. All rights reserved.
3 Maintenance
Note
32.
Type of oil and total amount is de-
tailed in Technical reference
manual - Lubrication in gearboxes.
Further information about how to
drain or fill with oil is found in sec-
tion
Changing oil, axis-4 primary
gearbox on page
149.
Continues on next page
Continued
109