ABB IRB 8700 Product Manual page 153

Hide thumbs Also See for IRB 8700:
Table of Contents

Advertisement

6
7
8
9
Product manual - IRB 8700
3HAC052853-001 Revision: M
Action
Remove the protection cap from the nipple
of the oil filling plug and connect the oil
dispenser.
Refill the gearbox with oil, using the oil
dispenser.
Note
The amount of oil to be filled depends on
the amount previously being drained.
Inspect the oil level.
Remove the oil dispenser and refit the
protection cap to the nipple of the oil filling
plug.
© Copyright 2015-2020 ABB. All rights reserved.
3.4.4 Changing oil, axis-4 primary gearbox
Note
Type of oil and total amount is detailed in
Technical reference manual - Lubrication
in gearboxes.
See
Type and amount of oil in gearboxes
on page
137.
Required oil level is: 0 - 10 mm below the
oil plug hole.
See
Inspecting the oil level in axis-4
primary gearbox on page
Continues on next page
3 Maintenance
Continued
108.
153

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 8700 - 550/4.20Irb 8700 - 800/3.50

Table of Contents