4 Repair
4.4.2 Refitting the cable harness
Continued
8
Connecting the axis-5 motor cables
1
2
Continues on next page
224
Action
Refit the cover.
Action
Push the motor cables in through the cable
gland opening.
Refit the cable gland cover.
Note
Replace the gasket if damaged.
© Copyright 2015-2020 ABB. All rights reserved.
Note
xx1500002722
Note
xx1500002717
Attachment screws: M5x16 (2 pcs)
xx1200001016
Product manual - IRB 8700