Product manual - IRB 8700
3HAC052853-001 Revision: M
Action
Apply flange sealant (Loctite 574) on the
contact surface between parallel arm and
counterweight.
Use caution and lift the counterweight up
onto the parallel arm.
Fit attachment screws with washers and
secure the counterweight to the parallel
arm.
Remove lifting accessories; lifting chains
and the lifting eyes.
© Copyright 2015-2020 ABB. All rights reserved.
4.5.6 Replacing the complete lower arm
Note
Flange sealant: Loctite 574
xx1600000049
xx1500001982
Attachment screws: M16x70 Gleitmo (10
pcs)
Tightening torque: 300 Nm
xx1500001981
Continues on next page
4 Repair
Continued