Action
Use the Sleeve KM nut, open and remove
the KM nut on the other side.
Remove gamma sealing and sealing ring.
Note
Continue the removal on the same side
until the shaft is removed completely.
Leave the other shaft fitted for now!
Remove the magnetic plug and wipe hole
and shaft end meticulously clean.
© Copyright 2015-2020 ABB. All rights reserved.
4.5.6 Replacing the complete lower arm
Note
xx1500002727
xx1500002728
xx1500003125
Continues on next page
4 Repair
Continued
365