ABB IRB 8700 Product Manual page 629

Hide thumbs Also See for IRB 8700:
Table of Contents

Advertisement

4
5
6
Removing the motor
1
2
Product manual - IRB 8700
3HAC052853-001 Revision: M
Action
Disconnect the motor cables.
Remove the cable gland cover.
Make sure the gasket is not damaged.
Tip
Make a note in which direction the cable
gland hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
Use caution and pull out the motor cables.
Action
DANGER
When releasing the holding brakes of the
motor, the lower arm and/or parallel arm
will be movable and may fall down! Before
continuing, the lower arm and parallel arm
must be secured!
In order to release the brakes, connect the
24 VDC power supply.
Connect connector R2.MP3:
pin 2 = 24V
pin 5 = 0V
© Copyright 2015-2020 ABB. All rights reserved.
4.8.4 Replacing the axis-3 gearbox
Note
xx1200001066
xx1200001067
Note
24 VDC power supply
Continues on next page
4 Repair
Continued
629

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 8700 - 550/4.20Irb 8700 - 800/3.50

Table of Contents