672-Part Peripheral Cabinet; Fd Peripheral Cabinet - Mitel SX-200 Practices

Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

General Descriotion
672-Port Control Cabinet
3.4
The SX-200
DIGITAL
672-Port
Control
cabinet,
shown
in Figure 3-4,
contains
the
Control shelf, Bay 0 in the lower left position,
Bay 1 on the lower right, and Bays 2 and
3 in the upper
shelf. The Control
cabinet
supports
up to three
6-circuit
power
fail
transfer
cards. The 672-port
configuration
is not available
with Generics
1001 and
1002.
Bay 0 contains:
1 Main Control
Card, 1 Bay Power Supply, 1 Switch Matrix Card, and
2 Floppy Disk Drives.
Bays 1 to 3 each contain:
1 Bay Power Supply, 1 Bay Control Card, and up to 8'Digital
Peripheral
cards.
672-Port Peripheral Cabinet
3.5
The
SX-200
DIGITAL
PABX 672-port
optional
Peripheral
cabinet
(shown
in
Figure 3-5) consists
of 4 digital bays with 96 ports each. Each bay is connected
to
and controlled
by Bay 0 in the Control
cabinet.
The 672-Port
Peripheral
cabinet
also
supports
three
6-circuit
power
fail transfer
cards,
for a system
total of 36 PFT
circuits.
Bays 4 to 7 each contain:
1 Bay Power Supply, 1 Bay Control Card, and up to 8 Digital
Peripheral
cards
Note:
An SX-200 DIGITAL 672-part
PABX may also be created by converting an installed
336-part
Control cabinet to a Peripheral cabinet and adding a new 672-part
Control
cabinet.
100 3-6
Revision 0
9109-096-l
OO-NA
Issue 1

Hide quick links:

Advertisement

Table of Contents
loading