Mitel SX-200 Practices page 587

Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

6
'
SMDR PROGRAMMING
AND
CONTROL
6. I-
The operation
of the SMDR
feature
is determined
during
initial installation
of the
system.
Programming
the SMDR feature
is part of the System
and Class of Service
\
Options
programming
known
collectively
as Customer
Data
Entry
(CDE).
The
operation
can be modified
at any time by the maintenance
person
from the CDE
terminal.
Table 6-1 shows
the Trunk SMDR
options
involved
and Table 6-2 shows
the Data SMDR
options
involved.
A brief description
of these options
is given below.
A complete
description
of the CDE forms
is given in Practice
9109-096-210-NA,
Customer
Data Entry. For a record of an outgoing
call to be generated,
SMDR
must
be enabled
in CDE Form 16, Trunk Groups.
A device accessing
a Trunk Group
with
SMDR
enabled
will generate
an SMDR
record
unless
COS Option
700, SMDR
-
Does Not Apply, is enabled
in that device's
Class of Service.
TRUNK SMDR and acd smdr Programming Options
6.2
The Trunk SMDR
and ACD SMDR
programming
options
are as follows:
l
Record Incoming Calls:
This COS option enables
SMDR for incoming
trunk calls.
Note: For modem pooling, if the Record Incoming Calls option is enabled, and the SMDR
buffers become full, new incoming CO calls will receive busy tone and new incoming
TIE, DID, or DISA trunks will receive reorder tone. These calls will not be accepted by
the PABX. Modem Pooling is not available in Generics 1001,1002
and 1005 FPKG 1
and LIT96.
9 Record Meter Pulses:
This COS option
causes
meter pulses generated
by the
Central
Office to be counted
and then reported
in the SMDR
record.
0 Drop Calls Less Than n Digits:
When this COS option is enabled,
outgoing
calls of
less than n digits are not reported
(where "n" is programmed
to be between
0 and 11
and 0 disables
the option).
l
Drop Incomplete Outgoing Calls:
When this COS option is enabled,
incomplete
outgoing
calls are not recorded.
Notes:
1. If the call duration is less than the programmed
value of the system timer
"Pseudo Answer Supervision Timer", the call is considered an incomplete
call.
2. If Trunk Circuit Descriptor Option "Far End Gives Answer Supervision"
is set
to YES, and ANSWER SUPERVISION
is not received, an SMDR record is
not generated.
9109-096-221
+'.JA
Issue 1
Revision 0
221
6-l

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents