HARDWARE OVERVIEW
General
4.1
The heart of the system
is the Main Control
Card (MCC),
a 16--bit microprocessor
,operating
at a clock frequency
of 8 megaHertz.
The Main Controller,
through
its
address,
data, and control
buses,
interfaces
to a floppy
disk unit, memory,
Direct
Memory
Access
Controller
(DMAC),
a Digital Signal
Processor
(DSP), a Message
Subsystem,
and a DX Matrix or Switch Matrix Card/Module.
In the 336and
456Port configurations,
the MCC controls digital Bays 1 and 2 directly.
In the 336-part
configuration,
the MCC controls
Bays 3 and 4 through
their Bay Control
Cards.
In the 456-par-t
configuration,
the MCC controls
Bay 3 through
its Bay Control
Card,
'and
controls
Bays
4 and
5 through
two
Digital
Interface
Cards
(DIC)
which
communicate
with the Main Control
Card via the DX module.
In the 48O-pot-t
configuration,
the MCC controls
Bays 3, 4, and 5 through
three DlCs
which communicate
with the Main Control
Card via the DX module.
In the 672-port
configuration,
the MCC controls
Bays 1 through
7 through
their Bay
Control
Cards; Bay 0 (which has no peripheral
cards) is controlled
directly through
the
Bay 0 backplane.
In the SX-ZOO FD system
configuration,
the MCC controls
the digital
bay in each
Peripheral
cabinet
through
the Peripheral
cabinet's
Bay Control
Card.
336,456,48&,
and 672- Port Configurations
4.2
The
336,
456-,
480-,
and 672-port
configurations
have
the following
main
hardware
components:
Main Control Card (MCC)
- performs
call processing
and maintains
overall control
through
communication
with the Bay Control
card or Peripheral
Control
card in each
bay. In 336
and 456-par-t
systems,
the MCC directly controls
Bays 1 and 2 (COMBO
backplane
only). The architecture
of the Main Control
Card varies according
to system
configuration.
Switch Matrix Card (SMC)
- required
only for a 672-par-t
system;
it is installed
in Bay
0. It is used to expand
the DX switching
matrix which in other configurations
is located
on the Main Control
Card. A DX Module
is not installed
on the MCC when
a SMC is
present.
Floppy Disk Drives
- two floppy disk drives store all system
software
and Customer
Data.
Upon power-up,
Call Processing
and Maintenance
software
are downloaded
9109-09~10O-NA