Control Resource Card; Electrical Description; 125 4-L - Mitel SX-200 Practices

Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

4
.
CONTROL RESOURCE CARD
4.1.
The Control
Resource
Card (CRC) provides
the miscellaneous
circuitry required
by
the Control
Cabinet
to support
the distributed
architecture
of the SX-ZOO FD. The
CRC functionally
resides
between
the Main
Control
Card
(MCC)
and the Fiber
Interface
Modules
(FlMs).
Removal
of the CRC will cause
System
Fail Transfer
(SFT) to be activated.
It will also cause the loss of the Fiber Maintenance
Links, the
loss of Terminal
and Printer Ports, and the loss of the Floppy Disk Drive Units.
The CRC is located
in the rightmost
slot of the Control
Cabinet
next to the Main Control
Card.
The card measures
279 mm x 368 mm (11 .O in. x 14.5 in.).
Note: The Control Resource Card is required
for the SX-200
FD. It is not available prior to
Generic 1005.
l-GGiil
The Control
Resource
Card must not be uplugged
under power.
4.2
The Control
Resource
Card provides:
9 Maintenance
Port arbitration
for local (Control)
or remote (Peripheral)
maintenance
sessions
l
Fiber Maintenance
Link multiplexer
. System
Fail Transfer
signal
l
Peripheral
RS232 terminal
connection
l
Controlling
circuitry for the 3.5 in. Disk Drive units
l
Surge Protection
for the Maintenance
and Printer Ports
Electrical Description
4.3
A Maintenance
Terminal
can be connected
to the Control
Cabinet
or to one of the
Peripheral
Bays. The Maintenance
Port arbitration
circuitry
monitors
the RS-232
Maintenance
Terminal
Transmit
Data lines of the Control
Cabinet
and the Peripheral
Bays,
When the arbitration
circuit senses
activity
(installer
or maintenance
person
pressing
any key) at a peripheral,
it switches
the terminal
connection
from
the
Control
Cabinet
to the Peripheral
Bay (or viceversa).
9109-096-l
25-NA
Issue 1
Revision 0
125 4-l

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents