Circuit Card Descriptions
Data from
one of the seven
Fiber
Maintenance
Links are switched
by the Fiber
Maintenance
Link multiplexer
onto Channels
2 to IO of the Control
Maintenance
Link.
The Fiber Maintenance
Links selection
bits (ID) are multiplexed
onto channel
Il.
One common
System
Fail Transfer
(SFT) signal driven by the SANITY
signal from the
Main control Card is provided.
Surge protection
for the Maintenance
and Printer Ports is provided
by transorb
diodes,
Fortroubleshooting
purposes,
four dip switches
are provided
on the CRC faceplate
to
allow a maintenance
person
to force connectivity
to either the Control
or Peripheral
Cabinet.
See Table 4-l
for the required
switch settings.
,
Switch Settings
Table 4-l Control
Resource
Card Switch Settings
Normal Operation
Forced Maintenance
to Control
Forced Maintenance
to Peripheral
Sl
Closed
Open
Cliled
Open
Switch Settings
s2
s3
Closed
Not Used
Open
Not Used
Closed
Not Used
s4
Not Used
Not Used
Not Used
I
I
I
I
Only one maintenance
sesslon,
at elther the Control
Cablnet or at one of the
Peripheral
Bays, Is allowed to be In progress
at one tlme.
125 4-2
Revision 0
9109-096-l
25-NA
Issue 1