Maintenance-Object Repair Procedures
Table 8-588. TEST #161 Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
1005
ABORT
This test aborts when it is run on a Stratum-4 system. Do not change
synchronization to Stratum 3 without consulting the synchronization plan
administrator for this switch.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1
FAIL
Either Reference A failed or CI card A failed. This condition usually indicates a
failure of the DS1 reference; however, there may also be a failure of the CI card
to which the reference is connected. The system technician dispatched to
investigate this problem should take a spare CI card in case the CI card caused
the failure. If you are NOT ON-SITE, use the following procedure:
1. Look for DS1-BD (DS1 Interface Circuit Pack) errors using the display
2. If there are no DS1-BD errors or after resolving every DS1-BD error, issue
1
FAIL
(continued)
If you are ON-SITE, use the following procedure:
1. Look for a red LED on CI card A (i.e., the left CI card). If there is a red
2. If a spare CI card is available, replace the suspect CI card. Otherwise,
3. Look for DS1-BD (DS1 Interface Circuit Pack) errors using the display
4. After every DS1-BD error has been resolved, then determine whether the
5. Check the DS1 reference A connections to the Stratum-3 clock.
6. To determine whether the alarm still exists, issue the test synchronization
8-1504
Issue 1 May 2002
error command. See the DS1-BD Maintenance documentation for
recommended strategy to resolve any DS1-BD errors found.
the test synchronization r 4 command to determine whether the alarm
still exists. If every test repetition passes, then the alarm no longer exists.
Otherwise, the system technician should be dispatched with a spare CI
card to use the following instructions on-site. (continued)
LED, then replace the CI card, if a spare is available. If no spare CI is
available on-site, proceed to Step 3. If after replacing the CI card, the red
LED on the new CI card lights also, then proceed to Step 3.
issue the test synchronization r 4 command to clear the alarm. If any
test repetitions fail, then follow the procedure for those failures.
error command. See the DS1-BD Maintenance documentation for
recommended strategy to resolve any DS1-BD errors found. If there are
no DS1-BD errors, then proceed to Step 5.
alarm still exists by issuing the test synchronization r 4 command to clear
the alarm. If any test repetitions fail, then follow the procedures for those
failures.
r 4 command to clear the alarm. If any test repetitions fail, then follow the
procedures for those failures.
Continued on next page