RCA, which must be used in order to select the card in the future
for data transfers. The card will then move into standby mode,
completing the identification procedure.
Single Block Write Operations
Block write operations typically consist of 512 bytes of data per block.
If the card is found to support other block lengths or the default block
length as specified in the CID register is not 512, the block length of the
RSI must be configured accordingly. The block length of the card and the
block length of the RSI must be configured for the same block size at all
times. The block length of the RSI is configured via the
field of the
RSI_DATA_CONTROL
It is important to pay attention as to when the data path state
machine is enabled and when data is written to the FIFO for trans-
fer to the card. Write transactions require that data be written after
the response has completed for the
data path state machine is enabled prior to sending the
WRITE_BLOCK
FIFO via the DMA or core until after the response has been
received as indicated by the
this procedure can result in data being written to the card in viola-
tion to the block write timing parameters, resulting in a data CRC
failure.
ADSP-BF50x Blackfin Processor Hardware Reference
Removable Storage Interface
register.
command, data must not be written to the transmit
CMD_RESP_END
DATA_BLK_LGTH
command. If the
WRITE_BLOCK
flag. Failure to adhere to
21-35
Need help?